pvc conduit need to be glued - ElectriciansForums.net Est.2006
May 7, 2012 · No I don't glue pvc conduit to be honest, especially if it's outside. I always cut the conduit so that there is a 2-3 mm gap where the conduit ends and the stop lip on the box, this to allow for any expansion in the summer.
Hdpe to pvc? - ElectriciansForums.net Est.2006
Oct 15, 2021 · Normal PVC solvent glue does not work on HDPE. There's very little that sticks to it which is why heat fusion is the normal choice. Is there is a compression (mechanical) connector option to attach a flange or rigid conduit spout that can then be connected to the PVC?
Connecting rigid conduit to flexible conduit - Electricians Forums ...
Jul 24, 2017 · Or is it acceptable to glue the flexible conduit into a coupler. I recently tried this method but found that the contractors pack of 20mm flexible conduit from my local wholesalers would not push easily into a coupler without distorting it a little.
How to get a weatherproof seal on conduit?
Sep 23, 2014 · Sometimes I'll use PVC adhesive (for PVC conduit, obviously): PVC Adhesive - Tin or this stuff is pretty good, although I've not tried it on conduit: Geocel The Works Sealant & Adhesive Clear 290ml | Weatherproof Sealants | Screwfix.com As above, I'll generally try not to drill holes in the top face of any electrical enclosure for use outside ...
Best way to bend 25mm PVC conduit? - Electricians Forums
Nov 9, 2017 · Past attempts to do this using nothing but a bending spring (originally bought for 22mm copper pipe) were not successful. I found that I could do the job if I warmed up the conduit with a heat gun, but have never been totally happy with the results, as the PVC develops obvious ripples at the heating points.
How can you Earth Bond plastic incoming mains water pipe?
Jan 11, 2011 · no mate copper incoming direct to stop tab then plastic in bathroom, goes underground and reappears near to combi which is the next closest place to put the bond. one next door has copper intake then about 2 metres plastic returning to copper in same room, so a clamp can go on to the coper near the stop tap. interested in your views on this as i still think a bond should be put in wherever the ...
Saddle / Fixing Spacings - ElectriciansForums.net Est.2006
Jul 11, 2019 · I have had a install job at the company I work for currently. It is pvc 20mm conduit run on the wall horizontally. Seeing that the 18th edition in reg (521.10.202) Note 3 says that plastic clips are not meant to be used as a sole means of support and suitably spaced metal fixings should be used.
New consumer unit close to gas pipe/meter - Electricians Forums
Oct 24, 2011 · When replacing a consumer unit. If the current rewireable board is only 80mm from gas pipe/meter can the new board be fitted there or does it have to be moved to comply with the minimum distance of 150mm. Not possible to fit close if so and would need to be moved over a meter to find space...
Gas pipes and cables | ElectriciansForums.net Est.2006 | Free ...
Jul 9, 2012 · if you look closley at the diagram on pge 18 of the OSG the gap needed between a cable and gas pipes or metering equipment is 25mm and this can be reduced if the gas pipe is pvc wrapped or a barrier of electrically insulating material is interposed, the distance from electrical accesories must be 150mm.
20mm PVC conduit crossover / hopover? - Electricians Forums
Nov 19, 2015 · I've never seen a pre-made "cross-over", presumably because if you wanted to cross a 4" soil pipe, a 40mm waste pipe and a 20mm conduit you'd have to buy three different size fittings. There would need to be hundreds of variants to cater for all possibilities.