Mar 6, 2025 · For buildings under PG III, IV, V and VII exceeding the habitable height of 10m, a fire engine accessway shall be located directly below the fire access openings to provide direct reach to the designated fire access panels.
Clause 4.2 Provision for external access to station for ... - SCDF
For aboveground stations exceeding the habitable height of 10m, fire access openings are required at every storey/ level, except the 1st storey, and shall face the fire engine accessway directly. a. Fire access openings shall be provided on …
The purpose of the access opening is to enable fire fighters to gain access from external to rescue any occupant who is trapped in the building and to allow fire fighting from the outside of building.
Fire Engine access on building structures. parallel to the collision load acting at a visible height of 0.75m above the carriageway. Imposed load reduction for foundation implemented in the structural design.
These requirements are specific to HDB and represent the standards of HDB public housing. Minimum 10% lighting and ventilation to all room areas. Minimum 5% ventilation to all bathrooms, store room and services rooms. Minimum 3.8m height clearance for drop-off porch not serving as fire engine access.
“Electromagnetic” or “electromechanical locking device” refers to a fail-safe device which provides access control. This device is designed to automatically unlock doors in the event of a fire, thereby helping to facilitate evacuation.
Fire engine accessways/roads are provided to ensure site accessibility for firefighting appliances during emergency operations. While most building developments are provided with a single entry/exit vehicle gantry point, there are also developments with …
Fire Code 2013 HB Chpt 4 Site Plan & External Fire Fighting
This requirement for fire engine access road shall not apply to non-residential standalone building, such as clubhouse, carpark, etc. (excluding guardhouse and substation) that are located within the housing development.
Fire Code - BuiltSearch
For buildings under PG III, IV, V and VII exceeding the habitable height of 10m, a fire engine accessway shall be located directly below the fire access openings to provide direct reach to the designated fire access panels.
Found this gem on google maps, a 4.5m high shelter over a ... - Reddit
Jun 2, 2020 · Would an emergency vehicle, say a firetruck need to go between those street lights and perhaps park on that long stretch of grass? It's for the fire fighting crew. Tall people need cover from rain and shine too. Fire engine access. These structures are pretty common in Singapore HDB estates so I'm surprised you bavent seen them before lol.